Septic & Utilities

Septic Backing Up at Breakup in Alaska: Causes and Fixes

MNA Construction··5 min read

A septic system backing up or running slow at spring breakup in Alaska usually means the drainfield is sitting in high groundwater or meltwater, a section frozen all winter has not thawed yet, or surface water is pouring into the tank through a lid or riser. Cut water use hard, keep surface water away from the tank, and do not have the tank pumped while the drainfield is flooded or saturated, because EPA warns an empty tank can try to float out of the ground. If the backups come back every spring, the field probably does not have enough separation from the water table.

This post is about getting through the next few weeks and keeping water out of the system. For the long-term question of whether your field has failed, see our post on failing drainfield signs.

Why septic systems back up at breakup

A drainfield works by letting effluent (the liquid that leaves the septic tank) soak into unsaturated soil. At breakup, the soil fills with water from above and below at the same time.

  • Groundwater rises into the drain rock. DEC requires 4 feet between the bottom of a conventional field and the seasonal high water table. A field that meets that in August may not in late April. When groundwater reaches the rock, effluent has nowhere to go.
  • Frost leaves from the top down. The top foot or two thaws while the ground below stays frozen. Meltwater sits on that frozen layer, saturating the soil over and around the field.
  • Pipes thaw unevenly. A line under a plowed driveway or path froze deepest and thaws last. A house can have a working field and a sewer line still plugged with ice.
  • Surface water gets into the tank. Snowmelt ponds over a settled tank and runs in through loose lids, cracked risers, or uncapped cleanouts. A tank that fills with meltwater pushes that water to a field that is already full.
  • Roofs and driveways drain onto the field. DEC's homeowner brochure tells owners to divert rainwater from driveways and roofs away from drainfields, because flooding the field keeps the soil from cleaning the wastewater.
  • A sump pump discharges into the house drain. If a crawlspace or basement sump that collects groundwater empties into the sewer line, breakup groundwater goes straight into the tank. Find out where yours discharges.

What to do when your septic backs up at breakup

  1. Cut water use now. EPA's flood guidance says to drastically reduce water use in the house. Take short showers, run only full loads, move laundry to a laundromat, and fix running toilets.
  2. Stop using the system if floodwater covers it. University of Minnesota septic guidance says not to use a system with floodwater over it.
  3. Hold off on pumping. EPA says do not pump the tank during flooded or saturated drainfield conditions. At best it is a temporary fix, and in saturated ground the empty tank can try to float, which breaks the inlet and outlet pipes.
  4. Call a pumper if sewage is coming into the house. That is the exception. Tell them the field is saturated and let them decide whether, and how much, to pump.
  5. Keep vehicles and equipment off the field. EPA warns that saturated soil compacts easily, and compaction can finish a field.
  6. Move meltwater away from the tank. Shovel a channel so ponded water over the tank runs off, and check that every lid, riser, and cleanout cap is on and tight.

If effluent comes to the surface, DEC's rules treat that as a system failure. The owner has to repair it as soon as practicable, clean it up, have it disposed of at an approved facility, and keep people out of the area until cleanup is done.

Is it breakup, or a failing system?

The timing of the symptoms is the best clue. A pumper's look inside the tank fills in the rest.

What you seeLikely causeWhat it means
Slow drains in late April, normal by JuneSeasonal high groundwater in the fieldThe field lacks separation; it will repeat every spring
Tank level rises right after a big melt or rainSurface water entering through lids or risersSeal and raise the risers; regrade over the tank
One low drain backs up, tank level normalIce still in the house sewer lineWait for thaw or have it steamed; fix the cover next fall
Wet ground or green strips over the field in JulyField no longer absorbingFailed field; plan a replacement
Pump alarm during breakupPump tank flooding or field refusing waterCall a pumper or installer

A backup that clears up by summer is still a warning. Each spring the field spends under water, it is not treating wastewater, and DEC counts surfacing effluent as failure the day it shows up. A new soils test shows how high the water comes and whether a replacement can be conventional or needs an engineered, raised design.

Prevention: keep water away from the tank and field

Most breakup backups can be cut down with dirt work and a few parts. The time to do it is summer, when the ground is dry enough to grade and compact.

  • Regrade over the tank. Backfill over a tank settles over time and leaves a low spot right where you do not want water. Fill it and slope the surface so melt runs away from the lids.
  • Raise and seal the risers. A riser that ends at grade takes in every drop of meltwater around it. Bring risers and cleanouts above grade, with tight lids and good seals. DEC's brochure advises leaving standpipes at least 24 inches above the surface, and tanks over 2,000 gallons need insulated, locking manhole risers.
  • Send roof and driveway water somewhere else. Downspout extensions, a swale, or a ditch can carry runoff around the field instead of across it.
  • Intercept groundwater with a curtain drain. A curtain drain is a gravel trench with perforated pipe, dug across the slope uphill of the field, that catches groundwater moving downhill and carries it around. It has to be designed with your installer or engineer, at the right distance from the field and in line with DEC separation rules, so it does not end up collecting effluent. Our post on French and curtain drain costs covers the build.
  • Do not stack plowed snow on the field. Natural snow insulates the system in winter. A plow pile from the driveway packs the snow and then dumps all its meltwater onto the field at breakup.
  • Fix the frozen sections. A line that freezes every winter and thaws last every spring needs more cover or insulation. Our post on frozen septic systems covers the fixes.

If the field sits in groundwater every spring no matter what you do on the surface, no amount of grading will change that. The field needs to be rebuilt higher, or moved to better ground.

Fix the drainage before next spring

MNA Construction regrades over tanks and drainfields, raises and resets risers, builds curtain drains and swales to move water around the system, and digs replacement fields with a DEC certified installer or engineer, in Kenai, Soldotna, and across the central peninsula. See our septic system services, then request a free estimate and tell us when the backups started and when they stopped.

Common questions

Should I pump my septic tank during spring breakup?
Not while the drainfield is flooded or saturated, unless sewage is backing into the house. EPA warns that pumping then is only a temporary fix and that an empty tank in saturated ground can try to float, breaking its pipes. Wait until the ground drains, and tell the pumper the conditions.
Why does my septic only back up in the spring?
On the Kenai Peninsula, the usual causes are groundwater rising into the drain rock, meltwater saturating the soil over a still-frozen layer, or surface water getting into the tank through lids and risers. If it happens every spring, the field probably does not have enough separation from the seasonal high water table.
Can I use my septic system when the yard is flooded?
Use as little water as possible, and stop using it if floodwater covers the tank or field. A flooded field cannot take effluent, so whatever you send down the drain has nowhere to go except back toward the house or up to the surface.
How do I keep meltwater out of my septic tank?
Make sure every lid, riser, and cleanout cap is on and sealed, and raise risers above grade if they end at ground level. Fill any low spot that has settled over the tank, slope the surface away, and send roof and driveway runoff around the system.

Planning excavation or site work in Southcentral Alaska?

MNA Construction is owner-operated and ready to help. Let's talk about your project.

Get a Free Quote