Site Prep

Frost Depth in Kenai, Alaska: How Deep Footings Must Go

MNA Construction··6 min read

The frost depth used for footings in Kenai and Soldotna is 42 inches: both cities list it in their building design criteria. Homer does not issue building permits, and outside city limits the Kenai Peninsula Borough has no building code, so nobody inspects footing depth there. Forty-two inches is the local benchmark, but frost reaches much deeper under plowed and bare ground.

That is the short version. The rest of this post covers where each number comes from, why the ground can freeze deeper than the code number, and what to do on a site with no inspector.

Frost depth on the Kenai Peninsula by jurisdiction

Where you are buildingFrost depth for footingsWho checks it
City of Kenai42 inches (2021 IRC with local amendments)City building official, (907) 283-8238
City of Soldotna42 inches (city design criteria)City building department, (907) 262-9107
City of HomerNo building code enforcementNo building inspection; a city zoning permit is required before clearing or new construction
City of SewardSet by the city's adopted codeSeward building department; call for the current value
Borough land outside cities (Sterling, Nikiski, Kasilof, Cooper Landing and others)No borough building codeNo borough building permit or inspection; lenders may require inspections

The City of Kenai residential permit packet lists a foundation frost depth of 42 inches, footings or piers at least 42 inches deep, and a minimum footing of 16 inches wide by 10 inches thick with two number 5 reinforcing bars. The City of Soldotna local design criteria list a 42 inch frost line, a 70 pound ground snow load, a winter design temperature of minus 18 degrees F, an air freezing index of 3,000, and a mean annual temperature of 35 degrees F. Homer's planning department states that the City of Homer does not issue building permits.

Footing depth is measured to the bottom of the footing, from finished grade. If you add fill or regrade after the footings go in, the depth changes with it.

Outside city limits: no code, same ground

A large share of the peninsula, including Sterling, Nikiski, and Kasilof, lies outside any city. The borough's permit list covers driveways, rights of way, and similar items, with no building permit. That means no one checks your footing depth.

Two groups can still hold you to a standard. Lenders are one: Alaska Housing Finance Corporation requires homes it finances to pass inspections by an authorized inspector, based on the International Residential Code with AHFC amendments, unless the home is in a city with an approved code program. The other is the next buyer, whose inspector will notice a heaving foundation.

The practical answer: build to at least 42 inches anywhere on the western peninsula, and go deeper or insulate where the ground will be bare in winter.

Why frost can go deeper than 42 inches

The 42 inch number is a design minimum for footings. On parts of a site, frost goes well past it.

Snow is insulation. Where snow stays on the ground, frost penetrates less. Where it gets plowed off, frost goes much deeper. For Anchorage, which has a design air freezing index of 3,200 degree days (close to the 3,000 Soldotna lists), engineers use a typical frost penetration of about 9 feet for road design, where pavement is plowed bare.

Soil type matters too. The HUD and NAHB guide to shallow foundations notes that dry, coarse gravel freezes faster and deeper than wet silt, but with no potential for frost damage. So a deep frost line in gravel is not a problem by itself. The trouble starts where frost reaches wet silt.

Places on a typical site where frost runs deeper than average:

  • Under driveways and parking pads that get plowed
  • Under unheated garages, shops, and covered decks
  • Along the north side of buildings, where snow is thin and sun never reaches
  • Under any footing next to a heated building that sits empty and cold through a winter

Which soils heave

Frost heave needs three conditions at the same time: frost-susceptible soil (a large silt fraction), enough water, and freezing temperatures reaching that soil. Remove one and heave stops. That is the basis for every frost protection method.

Silt is the problem soil because it pulls water up toward the freezing front, where it forms layers of ice called ice lenses. Those lenses lift whatever is above them. Clean sand and gravel drain freely and do not grow ice lenses.

On the western Kenai Peninsula, the common Soldotna soil series has 15 to 30 inches of ash-influenced silt loam over very gravelly sand. That silt cap is right where shallow footings would sit. Wet, low ground and muskeg add peat to the picture. Our post on house pad cost and quantities covers stripping that layer out and replacing it with non-frost-susceptible fill.

Seasonal frost and permafrost are different problems. University of Alaska Fairbanks Cooperative Extension describes permafrost as a concern in most of Interior Alaska and areas west and north of the Alaska Range. The Kenai Peninsula sits south of all of that. If you find ground on your lot that stays frozen through summer, stop and read our post on building on permafrost before you design anything.

What happens when footings are too shallow

A footing above the frost line sits on soil that freezes and expands under it every winter. The lift is rarely even, because snow cover, sun, and soil moisture vary around the building. One corner rises, another does not, and the frame racks.

Frozen soil also grips the sides of posts and foundation walls. This is called adfreeze, and it can lift a post even when the bottom sits below the frost line, if the post is backfilled with wet silt. Each spring the soil thaws and drops, but the post often does not settle all the way back. Over several winters it walks upward.

The signs are familiar to anyone who has owned an older Alaska house: doors that stick in March and swing free in July, diagonal drywall cracks from window corners, a deck that tilts away from the house, and a stoop that pulls away from the door. Fixing it after the fact means excavating and rebuilding footings with the house on top. Getting the depth right during foundation excavation costs far less.

Frost-protected shallow foundations: the insulated alternative

A frost-protected shallow foundation uses rigid foam insulation around the footing, and sometimes extending outward under the ground, to keep the soil below the footing from freezing. The HUD and NAHB guide notes that one inch of polystyrene insulation has about the same insulating value as 4 feet of soil.

The residential code allows this method for heated buildings in Table R403.3(1). At an air freezing index of 3,000, the table allows a footing as shallow as 16 inches, with R-7.8 vertical insulation on the foundation and horizontal insulation of R-6.5 along the walls and R-8.6 at the corners. Inside Kenai or Soldotna, check with the building official before designing one, since the city enforces its adopted edition of the code.

Limits that matter:

  • The code method applies only to buildings kept at a monthly average of at least 64 degrees F. Unheated garages, porches, and shops need a separate design under the ASCE 32 standard, with insulation under the entire building.
  • The design does not apply on permafrost.
  • Insulation within 12 inches of the surface must be protected by a slab or pavement, and the gravel layer under the insulation must drain.

The residential code also exempts some small buildings from frost protection: freestanding light-frame accessory buildings up to 600 square feet with eaves 10 feet or lower. The ground under them still heaves if it is wet silt, so a gravel base still pays off.

MNA Construction digs footings to frost depth, strips frost-susceptible silt, and builds the compacted gravel base and drainage that insulated foundations depend on, across the Kenai and Soldotna area and the rest of the peninsula. Request a free estimate with your foundation plan and we will tell you what the ground on your lot needs.

Common questions

What is the frost line depth in Soldotna, Alaska?
The City of Soldotna lists a frost line depth of 42 inches in its local design criteria, along with an air freezing index of 3,000. That is the minimum footing depth the city building department works from. Actual frost penetration can be deeper under plowed or bare ground.
Do I need a building permit outside city limits on the Kenai Peninsula?
The Kenai Peninsula Borough does not issue building permits or enforce a building code outside the cities. Borough driveway, floodplain, and habitat permits can still apply, and septic systems need state approval. If AHFC finances the home, it requires inspections by an authorized inspector.
How deep should deck posts or pole barn posts go on the Kenai?
Use at least the 42 inch frost depth that Kenai and Soldotna require for footings, and backfill around posts with clean gravel instead of silt to reduce adfreeze. Freestanding decks are exempt from the frost footing rule in the residential code, but posts set in wet silt will still heave.
Is permafrost a problem on the Kenai Peninsula?
Seasonal frost is the main concern on most of the peninsula. UAF Cooperative Extension places most permafrost risk in Interior Alaska and areas west and north of the Alaska Range. Ground that stays frozen through summer on your lot calls for a geotechnical engineer before design.

Planning excavation or site work in Southcentral Alaska?

MNA Construction is owner-operated and ready to help. Let's talk about your project.

Get a Free Quote